IEC 60811-203 pdf download

admin
IEC 60811-203 pdf download

IEC 60811-203 pdf download.ELECTRIC AND OPTICAL FIBRE CABLES – TEST METHODS FOR NON-METALLIC MATERIALS
1 Scope
This Part 203 of IEC 6081 1 gives the methods for measuring overall dimensions and is applicable to all types of cable, circular and flat.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 6081 1 -1 00:201 2, Electric and optical fibre cables – Test methods for non-metallic materials – Part 100: General
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 6081 1 -1 00 apply.
4 Test method
4.1 General This part of IEC 6081 1 shall be used in conjunction with IEC 6081 1 -1 00. Unless otherwise specified, tests shall be carried out at room temperature. The measurement of the overall dimensions over the insulation of cores or over the sheath may be required as individual tests or as steps in the procedure for carrying out other tests. The methods used in 4.2 below are for general use, except where the procedure for a particular test specifies a different or alternative method. In each case, the method of selecting samples shall be in accordance with the relevant cable standard. 4.2 Measuring procedure The measuring procedure shall be as follows: a) For cables with overall dimensions not exceeding 25 mm, the measurements shall be made by means of a micrometer, a profile projector or similar apparatus, in two directions perpendicular to each other. For measurements made in the course of routine tests, it is permissible to use a dial micrometer or a vernier calliper, care being taken to limit the pressure.b) If the overall diameter exceeds 25 mm, the circumference of the cable shall be measured by means of a measuring tape, and the diameter shall be calculated. Alternatively, a direct reading diameter tape can be used. c) For flat cables, the measurements shall be made along the major and minor axes of the cross-section by means of a micrometer, a profile projector or similar apparatus. Unless otherwise specified in the relevant cable design standard, the reading shall be made to one decimal place of a millimetre for dimensions up to and including 25 mm, and to the nearest 0,5 mm for dimensions exceeding 25 mm. 4.3 Evaluation of the measurement results The results shall be evaluated as specified in the test requirements of the relevant cable standard.
5 Test report